Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 19 de 19
Filter
1.
Acta cir. bras ; 33(2): 156-162, Feb. 2018. tab, graf
Article in English | LILACS | ID: biblio-886258

ABSTRACT

Abstract Purpose: To evaluate the concentration of transforming growth factor beta 1 (TGFB1) levels in a rat pleural effusion obtained by inoculation of intrapleural bacteria or turpentine through thoracentesis. Methods: Thirty-Nine Wistar rats were divided into three groups: Staphylococcus aureus (SA, n = 17); Streptococcus pneumoniae (SP, n = 12); and turpentine (control, n = 10). Pleural fluid was collected through ultrasound-guided thoracentesis 12 h, 24 h, and 36 h after instillation of bacteria or turpentine. Levels of TGFB1 were measured in pleural fluid. Results: At 12 h, mean TGFB1concentrations were 5.3450 pg/mL in the SA group, 5.3449 pg/mL in the SP group, and 5.3450 pg/mL in controls. At 24 h, they were 4.6700 pg/mL in the SA group, 4.6700 pg/mL in the SP group, and 4.6700 pg/mL in controls. At 36 h, they were 4.6699 pg/mL in the SA group and in control. No difference was observed among the groups in mean TGFB1concentration (p = 0.12); however, a significant intragroup reduction in mean TGFB1 was observed between 12 and 24 h (p < 0.01). Conclusion: The transforming growth factor beta 1 concentrations were not useful as a diagnostic tool or an early marker of infected pleural effusion.


Subject(s)
Animals , Male , Rats , Pleural Effusion/diagnosis , Empyema, Pleural/diagnosis , Transforming Growth Factor beta1/analysis , Pleural Effusion/complications , Bacteria/pathogenicity , Biomarkers/analysis , Empyema, Pleural/complications , Empyema, Pleural/microbiology , Rats, Wistar , Disease Models, Animal
2.
Clin. biomed. res ; 38(3): 301-304, 2018.
Article in Portuguese | LILACS | ID: biblio-1047009

ABSTRACT

A Artroplastia de Ressecção tipo Girdlestone (ARG) é um procedimento que altera o estilo de vida do indivíduo gerando fadiga precoce, instabilidade articular, distúrbio da marcha e discrepância de membros. Como medida auxiliar no processo de reabilitação podem ser utilizadas órteses. Contudo, não há no mercado nacional dispositivos adequados, sendo necessária a importação com custo elevado. Assim, este estudo desenvolveu e avaliou os efeitos e a segurança de um protótipo de órtese de quadril em uma paciente feminina submetida à ARG. O modelo proposto melhorou o desempenho físico e a funcionalidade e promoveu o alívio de dores osteomusculares. (AU)


Girdlestone resection arthroplasty (GRA) is a procedure that changes one's lifestyle, leading to early fatigue, joint instability, gait disorder and limb discrepancy. Orthoses can be used as an aid in the rehabilitation process. However, there are no adequate devices available in Brazil and the imported ones are high-cost. Thus, this study developed and evaluated the effects and safety of a hip orthosis prototype in a woman who underwent GRA. The proposed model improved physical performance and functionality and provided relief of musculoskeletal pain. (AU)


Subject(s)
Humans , Female , Middle Aged , Arthroplasty, Replacement, Hip , Hip Prosthesis , Technology Assessment, Biomedical , Evaluation of Results of Therapeutic Interventions , Health Care Costs
3.
J. bras. pneumol ; 41(2): 143-150, Mar-Apr/2015. tab, graf
Article in English | LILACS | ID: lil-745921

ABSTRACT

Objective: Few studies have evaluated the variability of the perception of dyspnea in healthy subjects. The objective of this study was to evaluate the variability of the perception of dyspnea in healthy subjects during breathing against increasing inspiratory resistive loads, as well as to assess the association between the level of perception of dyspnea and the level of physical activity. Methods: This was a cross-sectional study involving healthy individuals 16 years of age or older. Subjects underwent inspiratory resistive loading testing, in which the level of perception of dyspnea was quantified with the modified Borg scale. We also determined body mass indices (BMIs), assessed maximal respiratory pressures, performed pulmonary function tests, applied the international physical activity questionnaire (IPAQ)-long form, and conducted six-minute walk tests (6MWTs). The level of perception of dyspnea was classified as low (Borg score < 2), intermediate (Borg score, 2-5), or high (Borg score > 5). Results: We included 48 healthy subjects in the study. Forty-two subjects completed the test up to a load of 46.7 cmH2O/L/s. The level of perception of dyspnea was classified as low, intermediate, and high in 13, 19, and 10 subjects, respectively. The level of perception of dyspnea was not significantly associated with age, gender, BMI, IPAQ-long form score, maximal respiratory pressures, or pulmonary function test results. Conclusions: The scores for perceived dyspnea induced by inspiratory resistive loading in healthy subjects presented wide variability. The perception of dyspnea was classified as low in 31% of the subjects, intermediate in 45%, and high in 24%. There was no association between the level of perception of dyspnea and the level of physical activity (IPAQ or six-minute walk distance). .


Objetivo: Poucos estudos avaliaram a variabilidade da percepção da dispneia em indivíduos saudáveis. O objetivo deste estudo foi avaliar a variabilidade da percepção da dispneia em indivíduos saudáveis através do uso de cargas resistivas inspiratórias crescentes, assim como avaliar a associação entre o nível de percepção da dispneia e o nível de atividade física. Métodos: Estudo transversal realizado em indivíduos saudáveis com idade ≥ 16 anos. Os indivíduos foram submetidos ao teste de cargas resistivas inspiratórias, no qual o nível de percepção da dispneia foi quantificado pela escala de Borg modificada. Foram também determinados os índices de massa corpórea (IMC), pressões respiratórias máximas, testes de função pulmonar, international physical activity questionnaire (IPAQ)-long form, e testes de caminhada de seis minutos (TC6). Os indivíduos foram classificados em percepção baixa (Borg < 2), intermediária (Borg, 2-5) e alta (Borg > 5). Resultados: Foram incluídos no estudo 48 indivíduos saudáveis. Desses, 42 completaram o teste até a carga de 46,7 cmH2O/l/s. O nível de percepção da dispneia foi classificado como baixo, intermediário e alto em 13, 19 e 10 indivíduos, respectivamente. Não houve associações significativas do nível de percepção da dispneia com idade, sexo, IMC, IPAQ e testes de função pulmonar. Conclusões: Os escores da percepção da dispneia induzida por cargas resistivas inspiratórias em indivíduos saudáveis apresentaram uma ampla variabilidade. A percepção da dispneia foi classificada como baixa, intermediária e alta em 31%, 45% e 24%, respectivamente. Não houve associações entre o nível de percepção da dispneia e o nível de atividade física (IPAQ ou distância no TC6). .


Subject(s)
Adolescent , Adult , Female , Humans , Male , Middle Aged , Dyspnea/physiopathology , Exercise Test , Inhalation/physiology , Body Mass Index , Brazil , Cross-Sectional Studies , Dyspnea/etiology , Inspiratory Capacity , Perception , Prospective Studies , Respiratory Function Tests , Severity of Illness Index , Surveys and Questionnaires
4.
J. bras. pneumol ; 40(3): 222-228, May-Jun/2014. tab, graf
Article in English | LILACS | ID: lil-714687

ABSTRACT

Objective: To evaluate the behavior of oxygen saturation curves throughout the six-minute walk test (6MWT) in patients with COPD. Methods: We included 85 patients, all of whom underwent spirometry and were classified as having moderate COPD (modCOPD, n = 30) or severe COPD (sevCOPD, n = 55). All of the patients performed a 6MWT, in a 27-m corridor with continuous SpO2 and HR monitoring by telemetry. We studied the SpO2 curves in order to determine the time to a 4% decrease in SpO2, the time to the minimum SpO2 (Tmin), and the post-6MWT time to return to the initial SpO2, the last designated recovery time (RT). For each of those curves, we calculated the slope. Results: The mean age in the modCOPD and sevCOPD groups was 66 ± 10 years and 62 ± 11 years, respectively. At baseline, SpO2 was > 94% in all of the patients; none received supplemental oxygen during the 6MWT; and none of the tests were interrupted. The six-minute walk distance did not differ significantly between the groups. The SpO2 values were lowest in the sevCOPD group. There was no difference between the groups regarding RT. In 71% and 63% of the sevCOPD and modCOPD group patients, respectively, a ≥ 4% decrease in SpO2 occurred within the first minute. We found that FEV1% correlated significantly with the ΔSpO2 (r = −0.398; p < 0.001), Tmin (r = −0.449; p < 0.001), and minimum SpO2 (r = 0.356; p < 0.005). Conclusions: In the sevCOPD group, in comparison with the modCOPD group, SpO2 was lower and the Tmin was greater, suggesting a worse prognosis in the former. .


Objetivo: Avaliar o comportamento da curva de saturação de oxigênio durante o teste de caminhada de seis minutos (TC6) em pacientes com DPOC. Métodos: Incluímos 85 pacientes e todos realizaram espirometria, sendo classificados como portadores de DPOC moderada (DPOCm, n = 30) ou grave (DPOCg, n = 55). Todos os pacientes realizaram TC6 em um corredor de 27 m com monitoramento contínuo da SpO2 e FC por telemetria. A partir das curvas de SpO2, foram analisados os tempos para atingir a queda de 4% da SpO2, para atingir a SpO2 mínima (Tmin) e para a recuperação da SpO2 após o TC6 (TR). Foram calculadas as inclinações dessas curvas. Resultados: A média de idade nos grupos DPOCm e DPOCg foi de 62 ± 11 anos e 66 ± 10 anos, respectivamente. Todos os pacientes iniciaram o teste com SpO2 > 94%, nenhum recebeu suplementação de oxigênio durante o TC6, e não houve interrupções. A distância percorrida no TC6 não apresentou diferença significativa entre os grupos. Os menores valores da SpO2 ocorreram no grupo DPOCg. Não houve diferença no TR entre os grupos, e 71% e 63% dos pacientes nos grupos DPOCg e DPOCm, respectivamente, apresentaram queda de SpO2 ≥ 4% até o primeiro minuto. O VEF1% apresentou correlações significativas com ΔSpO2 (r = −0,398; p < 0,001), Tmin (r = −0,449; p < 0,001) e SpO2 mínima (r = 0,356; p < 0,005). Conclusões: As curvas dos pacientes do grupo DPOCg em relação às do grupo DPOCm apresentaram valores menores de SpO2 e maior Tmin, sugerindo um pior prognóstico nos primeiros. .


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Oxygen Consumption , Pulmonary Disease, Chronic Obstructive/physiopathology , Walking/physiology , Exercise Test , Exercise Tolerance , Maximal Expiratory Flow-Volume Curves , Oxygen/metabolism , Pulmonary Disease, Chronic Obstructive/blood , Pulmonary Disease, Chronic Obstructive/classification , Spirometry
5.
J. bras. pneumol ; 37(6): 745-751, nov.-dez. 2011. ilus, tab
Article in Portuguese | LILACS | ID: lil-610906

ABSTRACT

OBJETIVO: Identificar o papel do broncodilatador no tempo de apneia voluntária máxima em pacientes com distúrbios ventilatórios obstrutivos (DVOs). MÉTODOS: Estudo caso-controle incluindo pacientes com DVOs e grupo controle. Foram realizadas espirometrias antes e após o uso de broncodilatador, assim como testes de apneia respiratória, utilizando-se um microprocessador eletrônico e um pneumotacógrafo como transdutor de fluxo. As curvas de fluxo respiratório foram exibidas em tempo real em um computador portátil, e os tempos de apneia voluntária inspiratória e expiratória máximos (TAVIM e TAVEM, respectivamente) foram determinados a partir do sinal adquirido. RESULTADOS: Um total de 35 pacientes com DVOs e 16 controles foram incluídos no estudo. O TAVIM sem o uso de broncodilatador foi significativamente menor no grupo DVO que no grupo controle (22,27 ± 11,81 s vs. 31,45 ± 15,73; p = 0,025), mas essa diferença não foi significativa após o uso de broncodilatador (24,94 ± 12,89 s vs. 31,67 ± 17,53 s). Os valores de TAVEM foram significativamente menores no grupo DVO que no grupo controle antes (16,88 ± 6,58 s vs. 22,09 ± 7,95 s; p = 0,017) e após o uso de broncodilatador (21,22 ± 9,37 s vs. 28,53 ± 12,46 s; p = 0,024). CONCLUSÕES: Estes resultados fornecem uma evidência adicional da utilidade clínica do teste de apneia na avaliação da função pulmonar e do papel do broncodilatador nesse teste.


OBJECTIVE: To identify the role of bronchodilators in the maximal breath-hold time in patients with obstructive lung disease (OLD). METHODS: We conducted a case-control study including patients with OLD and a control group. Spirometric tests were performed prior to and after the use of a bronchodilator, as were breath-hold tests, using an electronic microprocessor and a pneumotachograph as a flow transducer. Respiratory flow curves were displayed in real time on a portable computer. The maximal breath-hold times at end-inspiratory volume and at end-expiratory volume (BHTmaxV EI and BHTmaxV EE, respectively) were determined from the acquired signal. RESULTS: A total of 35 patients with OLD and 16 controls were included. Prior to the use of a bronchodilator, the BHTmaxV EI was significantly lower in the OLD group than in the control group (22.27 ± 11.81 s vs. 31.45 ± 15.73 s; p = 0.025), although there was no significant difference between the two groups in terms of the post-bronchodilator values (24.94 ± 12.89 s vs. 31.67 ± 17.53 s). In contrast, BHTmaxV EE values were significantly lower in the OLD group than in the control group, in the pre- and post-bronchodilator tests (16.88 ± 6.58 s vs. 22.09 ± 7.95 s; p = 0.017; and 21.22 ± 9.37 s vs. 28.53 ± 12.46 s; p = 0.024, respectively). CONCLUSIONS: Our results provide additional evidence of the clinical usefulness of the breath-hold test in the assessment of pulmonary function and add to the existing knowledge regarding the role of the bronchodilator in this test.


Subject(s)
Humans , Middle Aged , Bronchodilator Agents/adverse effects , Lung Diseases, Obstructive/physiopathology , Respiration/drug effects , Case-Control Studies , Forced Expiratory Flow Rates/drug effects , Prospective Studies , Time Factors
6.
Arq. neuropsiquiatr ; 69(6): 943-948, Dec. 2011. ilus, tab
Article in English | LILACS | ID: lil-612638

ABSTRACT

Quantitative sensory testing (QST) is defined as the determination of thresholds for sensory perception under controlled stimulus. Our aim was to validate a new QST device for Brazilian sample. In 20 healthy adults, thermoalgesic thresholds were assessed using a QST prototype (Heat Pain Stimulator-1.1.10; Brazil). A 30 × 30 mm² thermode with a 1°C/s stimulus change rate were applied. Thresholds of three consecutive stimuli were averaged in two different sessions separated by at least two weeks. Additionally long thermal heat pain stimulus was performed. To evaluate the consistency of our method we also analyzed 11 patients with small fiber neuropathy. Results showed good reproducibility of thermal perception thresholds in normal individuals and plausible abnormal thresholds in patients. We conclude that our QST device is reliable when analyzing the nociceptive pathway in controls and patients.


Teste de quantificação sensitiva (TQS) significa determinação de limiares de percepção sensitiva frente a um estímulo de intensidade controlada. Nosso objetivo foi validar um novo equipamento de TQS adaptado à população brasileira. Em 20 adultos saudáveis, limiares termoalgésicos foram avaliados, utilizando um aparelho protótipo do TQS (Heat Pain Stimulator-1.1.10; Brazil). Foi utilizado um termodo de 30 × 30 mm², com estímulo térmico de 1°C/s. A média dos limiares de três estímulos consecutivos foi obtida em duas sessões diferentes, separadas por pelo menos 2 semanas. Adicionalmente, foram aplicados estímulos térmicos dolorosos de longa duração. Para avaliar a consistência do nosso método, foram também analisados 11 pacientes com neuropatia de fibras finas. Os resultados mostraram boa reprodutibilidade dos limiares de percepção nos indivíduos saudáveis, assim como limiares anormais nos pacientes. Em conclusão, nosso aparelho de TQS apresentou boa confiabilidade ao analisar a via nociceptiva de controles e pacientes.


Subject(s)
Adult , Female , Humans , Male , Neuralgia/diagnosis , Pain Measurement/instrumentation , Pain Threshold/physiology , Peripheral Nervous System Diseases/diagnosis , Sensory Thresholds/physiology , Thermosensing/physiology , Case-Control Studies , Neuralgia/physiopathology , Peripheral Nervous System Diseases/physiopathology , Reference Values , Reproducibility of Results
7.
Rev. Col. Bras. Cir ; 38(6): 412-416, nov.-dez. 2011. ilus, tab
Article in Portuguese | LILACS | ID: lil-611532

ABSTRACT

OBJETIVO: Desenvolver, experimentalmente, malácia e estenose traqueal para testar novos modelos de órteses traqueais. MÉTODOS: Ressecamos três anéis cartilaginosos da traqueia cervical de cães no grupo A (n=5) e seis anéis no grupo B (n=4) para produzir malácia. Logo após, a mucosa da região com malácia recebeu aplicações de uma solução de hidróxido de sódio (NaOH) a 23 por cento, e os animais eram acompanhados com exames broncoscópicos para observar o desenvolvimento de estreitamento da luz da via aérea. Quando a estenose era de mais de 50 por cento da luz, ou havia sinais mínimos de insuficiência ventilatória, os animais eram sacrificados. O segmento de via aérea estreitada foi então coletado para análise histológica e era calculada a área de luz residual do segmento traqueal com estenose e malácia. RESULTADOS: Na análise histológica, foi constatada fibrose na submucosa e adventícia, associada a granulomas na mucosa. A luz residual média dos segmentos com estenose foi de 9 por cento e 12 por cento nos grupos A e B, respectivamente, (p>0,05). CONCLUSÃO: A combinação da ressecção de anéis cartilaginosos e da aplicação de NaOH 23 por cento na mucosa respiratória promoveu uma estenose traqueal intensa, porém esteve associada à perda de animais. Novos estudos são necessários para verificar se o emprego isolado de uma das técnicas seria mais seguro e eficaz para desenvolver estenose traqueal.


OBJECTIVE: To experimentally develop tracheal stenosis and malacia to test new models of tracheal stents. METHODS: We resected three cartilaginous rings from the cervical trachea of dogs in group A (n = 5) and six rings in group B (n = 4) to produce malacia. The mucosa of the region with malacia then received applications of a solution of sodium hydroxide (NaOH) at 23 percent, and the animals were accompanied with bronchoscopic examinations to observe the development of luminal narrowing of the airway. When the stenosis was of more than 50 percent or there were minimal signs of ventilatory failure, the animals were sacrificed. The segment of narrowed airway was then collected for histological analysis and calculation of the area of residual lumen in the tracheal segment with stenosis and malacia. RESULTS: In histological analysis, fibrosis was found in the submucosa and adventitia, associated with granulomas in the mucosa. The average residual lumen of the segments with stenosis was 9 percent and 12 percent in groups A and B, respectively (p> 0.05). CONCLUSION: The combination of resection of the cartilaginous rings and the application of 23 percent NaOH in the respiratory mucosa promoted severe tracheal stenosis, but was associated with loss of animals. Further studies are needed to verify that the isolated use of one of the techniques would be safer and more effective to develop tracheal stenosis.


Subject(s)
Animals , Dogs , Female , Male , Disease Models, Animal , Tracheal Stenosis , Instillation, Drug , Mucous Membrane , Sodium Hydroxide/administration & dosage , Trachea/surgery
8.
Rev. HCPA & Fac. Med. Univ. Fed. Rio Gd. do Sul ; 30(2): 125-130, 2010. ilus, graf, tab
Article in Portuguese | LILACS | ID: biblio-834341

ABSTRACT

Introdução: Diversas técnicas foram propostas para avaliação da musculatura do assoalho pélvico, porém, nenhum método mostrou-se capaz de medir as duas funções desses músculos: elevação e força de compressão. Na rotina de avaliação clínica é comumente empregada a palpação vaginal e, especialmente, o escore de Oxford modificado; entretanto, alguns trabalhos questionam a sensibilidade da escala de Oxford e sua correlação com medidas objetivas de força de contração muscular. Objetivo: neste estudo, propõe-se correlacionar as variáveis medidas na perineometria com o escore de Oxford modificado. Métodos: foram incluídas no estudo 45 pacientes com incontinência urinária que procuraram o ambulatório de Uroginecologia do Hospital de Clínicas de Porto Alegre. As pacientes foram submetidas à palpação vaginal, realizada por uma fisioterapeuta treinada na escala de Oxford, e a medição da força de compressão da musculatura pélvica por meio de balonete conectado a transdutor de pressão. As duas avaliações foram realizadas no mesmo dia. Resultados: encontrou-se correlação significativa (P <0,001) entre o escore de Oxford e as variáveis pressão máxima de contração e tempo de ativação muscular com coeficientes de Pearson de 0,69 e -0,532, respectivamente. Contudo, observa-se uma superposição entre as medidas perineométricas e do escore de Oxford entre categorias adjacentes. Conclusões: Os resultados mostram que apesar de estar incorporada a rotina clínica de avaliação, deve haver restrições quanto ao uso do escala de Oxford com propósitos científicos.


Background: Several techniques have been proposed for the assessment of pelvic floor muscles; however, none of them were able to measure the two main functions of these muscles: lifting and compressive force. Vaginal palpation and especially the Modified Oxford Scale (MOS) are frequently used during routine clinical evaluation, but some studies have questioned the sensitivity of the MOS and its correlation with objective measurements of muscle contraction force. Aim: the objective of this study is to correlate perineometry measurements with the MOS.Methods: Forty-five patients with urinary incontinence treated at the Urogynecology Outpatient Clinic of Hospital de Clínicas de Porto Alegre were included. The patients were submitted to vaginal palpation performed by a physical therapist trained in the MOS. The compression force of their pelvic muscles was measured by means of an air-filled ballonet connected to a pressure transducer. Both tests were carried out on the same day. Results: we found significant correlation (P < 0.001) between the MOS and the variables maximum contraction pressure andmuscular activation time with Pearson's coefficients of 0.69 and -0.532, respectively. However, we found overlapping results between the perineomtry measurements and the MOS scores in neighboring categories. Conclusions: these findings show that, although incorporated into routine clinical evaluation, there should be restrictions to the use of the MOS for scientific purposes.


Subject(s)
Humans , Female , Young Adult , Middle Aged , Muscle Contraction/physiology , Pelvic Floor/physiopathology , Physical Therapy Modalities/instrumentation , Urinary Incontinence/physiopathology , Manometry/instrumentation , Palpation/instrumentation
9.
J. bras. pneumol ; 34(1): 21-26, jan. 2008. ilus, graf
Article in English, Portuguese | LILACS | ID: lil-474293

ABSTRACT

OBJETIVO: Descrever o desenvolvimento de uma órtese de silicone e os testes in vivo de compatibilidade e aplicabilidade na traquéia canina normal. MÉTODOS: Quatro densidades de silicone foram testadas para a obtenção de protótipos. Para cada densidade, foi calculada a pressão exigida para causar a compressão, considerando-se uma área de contato de 1 cm² e uma redução de 30 por cento no diâmetro. A densidade selecionada foi 70-75 Shore A hardness. Adicionou-se sulfato de bário em pó ao silicone para tornar a órtese desenvolvida radiopaca e facilmente identificável ao exame radiológico. A órtese desenvolvida apresenta superfície externa corrugada com arcos salientes e descontínuos, semelhantes aos anéis traqueobrônquicos, para intercalação e fixação nas vias aéreas inferiores, superfície interna polida e extremidades lisas que evitam o dano por fricção. O protótipo considerado como sendo o mais adequado em termos de rigidez e flexibilidade foi implantado broncoscopicamente em traquéias caninas normais. Os animais foram sacrificados após oito semanas, e a traquéia foi removida para análise anatomopatológica. RESULTADOS: Não houve complicações após a implantação das órteses. Nenhuma precisou ser removida, e todas estavam bem posicionadas ao final de oito semanas. O estudo histopatológico mostrou que a membrana basal epitelial foi preservada. Foram observados pontos focais de desnudamento epitelial, leve infiltrado inflamatório sob a mucosa e, mais raramente, tecido de granulação com neoformação vascular e ausência de microorganismos. CONCLUSÕES: A órtese desenvolvida mostrou resistência aos esforços mecânicos e biocompatibilidade, não provocando reação tecidual adversa na traquéia canina, além de permanecer íntegra ao final do experimento.


OBJECTIVE: To describe the development of a silicone stent and perform in vivo testing for biocompatibility/applicability in the normal canine trachea. METHODS: Four different densities were tested in order to obtain the silicone prototypes. The pressure required for compression considering a contact area of 1 cm2, and a 30 percent reduction in diameter was calculated for each density. The best density was 70-75 Shore A hardness. Powdered barium sulfate was added to the silicone to make the stent radiopaque and easily identifiable in radiological imaging. This novel stent presents a corrugated external surface with discontinuous and protruding arcs resembling the tracheobronchial rings (for intercalation and fixation in the lumen of the lower airways), a highly polished inner surface and smooth extremities (to prevent friction-related damage). The prototype considered most appropriate in terms of rigidity and flexibility was bronchoscopically implanted in normal canine tracheas. After eight weeks, the animals were euthanized, and the tracheas were removed for anatomopathological analysis. RESULTS: There were no postimplantation complications, and none had to be removed. After eight weeks, the devices were found to be well-positioned. Histopathology revealed a well-preserved epithelial basal membrane, foci of denuded epithelium, mild submucosal inflammatory infiltrate with scattered granulation tissue, vascular neoformation, and no microorganisms. CONCLUSIONS: The stent developed proved resistant to mechanical stress, biocompatible in the canine trachea and well-preserved at the study endpoint.


Subject(s)
Animals , Dogs , Biocompatible Materials , Implants, Experimental , Stents , Tracheal Stenosis/therapy , Compressive Strength , Disease Models, Animal , Materials Testing , Prosthesis Design , Silicones , Stress, Mechanical , Trachea/anatomy & histology
10.
Med. reabil ; 26(3): 81-88, set.-dez. 2007. ilus, graf
Article in Portuguese | LILACS | ID: lil-474079

ABSTRACT

Indivíduos com lesão na coluna espinhal apresentam disfunções urinárias associadas, que variam de acordo com o nível da lesão. O correto acompanhamento e tratamento destes problemas são importantes para garantir a saúde e a qualidade de vida. Diversas técnicas são propostas para tratamento desses pacientes como cateterização, uso de absorventes e coletores de urina, procedimentos cirúrgicos e medicamentos. Neste artigo, dá-se especial atenção aos métodos de tratamento da disfunção urinária causados por lesão espinhal que empregam estimulação elétrica através da estimulação das raízes sacrais anteriores, neuromodulação, ativação seletiva das raízes sacrais e microestimulação espinhal.


Subject(s)
Humans , Male , Female , Electric Stimulation , Spinal Cord Injuries , Urinary Bladder, Neurogenic , Urinary Incontinence
11.
J. pneumol ; 28(2): 84-93, mar.-abr. 2002. ilus, tab
Article in Portuguese | LILACS | ID: lil-338929

ABSTRACT

O tratamento cirúrgico do paciente com estenose traqueobrônquica exige uma avaliação individualizada em razão da complexidade de sua origem, sendo a traqueoplastia considerada a modalidade ideal. As causas mais comuns de estenose são devidas à intubação traqueal e ao desenvolvimento de neoplasias e estas condições são justamente as que mais se beneficiam com o tratamento endoscópico quando a correção cirúrgica não está indicada. Na atualidade, os meios endoscópicos incluem a aplicação de diversos tipos de laser e sondas de dilatação, habitualmente com o uso de broncoscópio rígido, e emprego de radioterapia e órteses, separadamente ou em associação. Basicamente, as órteses são de dois tipos: metálicas e de silicone. As metálicas têm sua indicação mais freqüente para os casos de traqueomalacia e estenoses por compressão neoplásica extrínseca. Nos casos de obstrução da via aérea por inflamação aguda, restrita à sua luz ou sem envolvimento mais profundo da parede traqueobrônquica, ou em presença de neoplasia endoluminal, é recomendável a órtese de silicone. Embora em algumas situações essas diversas formas de tratamento possam ser intercambiáveis, não costumam ser a regra. Portanto, a estratégia terapêutica visando à resolução mais eficaz da estenose traqueobrônquica baseia-se na seleção dos métodos empregados desde o primeiro tratamento


Subject(s)
Humans , Tracheal Stenosis/surgery , Prostheses and Implants/methods , Stents , Prostheses and Implants/instrumentation
12.
Acta fisiátrica ; 8(2): 63-66, ago. 2001. ilus
Article in Portuguese | LILACS | ID: lil-301594

ABSTRACT

O trabalho descreve o desenvolvimento de um dispositivo que emula um mouse serial Microsoft. Este dispositivo permite ao deficiente físico tetraplégico acessar os recursos de informática em ambiente Windows 95/98 (ler e editar textos, navegar na Internet e utilizar o correio eletrônico) e auxilia o paciente de doenças degenerativas do sistema neuromuscular, como a esclerose lateral amiotrófica (ELA), com disartria, a comunicar-se com as pessoas ao seu redor. O movimento do cursor na tela do computador é produzido a partir do movimento de flexão e extensão da cabeça do usuário, sendo utilizado para medir os ângulos de inclinação um sensor de aceleração estática e dinâmica de dois eixos. Para emular o botão do mouse, são captados os sinais EMG (eletromiográficos) produzidos a partir do movimento voluntário dos músculos mímicos da região frontal do usuário. O processamento digital é realizado por microcontrolador de oito bits e os dados são transmitidos para um computador padrão IBM-PC através da interface RS232C.


Subject(s)
Quadriplegia , User-Computer Interface , Amyotrophic Lateral Sclerosis , Computer User Training , Dysarthria
13.
Rev. bras. ortop ; 34(9/10): 529-534, set.-out. 1999. ilus, graf
Article in Portuguese | LILACS | ID: lil-360866

ABSTRACT

Recorrer a banco de ossos tem sido cada vez mais necessário nos últimos anos em virtude do aumento do número de cirurgias como: tumores ósseos, artrodeses de coluna, revisões de artroplastia total de quadril e traumatismos com perda óssea. Tem-se tentado criar alternativas de enxerto ósseo, como o uso de osso liofilizado, tanto bovino quanto humano. Os processos de liofilização e o tempo de reidratação do osso antes de sua utilização transoperatória têm sido implicados na alteração das propriedades biomecânicas do osso. Este trabalho comparou a resistência à compressão in vitro do osso bovino congelado e do osso bovino liofilizado reidratado. Utilizaram-se cilindros de 10 x 8mm provenientes de côndilos femorais bovinos, que foram testados em uma máquina de compressão automatizada. Não foi encontrada diferença estatisticamente significativa entre os grupos estudados. O enxerto ósseo bovino congelado e posteriormente descongelado durante uma hora suporta as mesmas cargas compressivas e possui a mesma razão de deformação que o osso bovino liofilizado e reidratado durante 90 minutos antes do teste ou reidratado no momento do teste. O processo conjunto de liofilização e reidratação do osso não altera as suas propriedades biomecânicas de compressão.


Subject(s)
Animals , Cattle , Bone Transplantation , Transplantation, Heterologous , Biomechanical Phenomena , Freeze Drying
14.
Rev. HCPA & Fac. Med. Univ. Fed. Rio Gd. do Sul ; 19(2): 205-7, ago. 1999. ilus, graf
Article in Portuguese | LILACS | ID: lil-285213

ABSTRACT

Este artigo apresenta a descrição de um microcautério otológico com dispositivos de aspiração e descolamento para utilização em cirurgia otológica. O microcautério foi desenvolvido no Hospital de Clínicas de Porto Alegre, pelos setores de Engenharia Biomédica e Otorrinolaringologia


Subject(s)
Humans , Otologic Surgical Procedures/instrumentation , Cautery/instrumentation , Cautery/methods
16.
Rev. bras. otorrinolaringol ; 64(6,pt.1): 571-6, nov.-dez. 1998. ilus, tab
Article in Portuguese | LILACS | ID: lil-232431

ABSTRACT

O trabalho avaliou cirurgias de ouvido médio em seres humanos, realizadas com microcautério com dispositivo de aspiraçäo e descolamento, concebido pelo primeiro autor, em comparaçäo com cirurgias do mesmo tipo, realizadas sem uso do dispositivo. Vinte e quatro pacientes com indicaçäo para estapedectomias e timpanoplastias unilaterais ou bilaterais foram selecionados. Foram excluídos pacientes com doenças sistêmicas como hipertensäo arterial sistêmica näo controlada e discrasias sanguíneas. Os pacientes foram divididos em dois grupos: 12 foram operados com o microcautério; 12, sem uso de cautério. O microcautério permite controle de tempo de exposiçäo e temperatura em baixas potências de saída (máximo de 35 W). A corrente elétrica concentrada pode explodir as células do tecido ou aquecer localmente o tecido. Isto permite a execuçäo de corte, cauterizaçäo e descolamento em regiöes de difícil acesso. As cirurgias foram gravadas em vídeo e avaliadas por dois cirurgiöes otológicos. A avaliaçäo foi cega: os cirurgiöes näo sabiam quais procedimentos haviam sido executados com o microcautério. Os procedimentos foram qualificados como ótimo, Bom, Regular ou Ruim. O parâmetro utilizado na avaliaçäo foi hemostasia. Os avaliadores qualificaram como ótimo o resultado global de todas as cirurgias realizadas com o microcautério. No grupo controle, o avaliador 1 qualificou 42 por cento das cirurgias como Ruim e 58 por cento como Regular. O avaliador 2 qualificou 25 por cento das cirurgias do grupo controle como Ruim e 75 por cento como Regular. O uso do microcautério demonstrou benefícios concretos, quando comparado com métodos convencionais. Portanto, consideramos aconselhável sua aplicaçäo neste tipo de cirurgia


Subject(s)
Humans , Cautery/instrumentation , Electrosurgery/instrumentation , Stapes Surgery , Tympanoplasty
17.
Rev. bras. ortop ; 32(6): 462-8, jun. 1997. ilus, tab, graf
Article in Portuguese | LILACS | ID: lil-206769

ABSTRACT

Dois métodos de fixaçao da osteotomia de Hohmann para hallux valgus foram comparados biomecanicamente usando ossos de cadáveres humanos frescos. As osteotomias foram realizadas através dos colos dos primeiros metatarsianos e fixados com fio de Kirschner de 2,0mm e banda de tensÝo capsular em um grupo, e com parafuso de 3,5mm, utilizando técnica de compressao interfragmetar ebanda de tensao capsular, no outro grupo. Os espécimes foram testados utilizando-se aparelho manufaturado em conjunto com o Serviço de Engenharia Biomédica, tendo como finalidade determinar a carga aplicada e o deslocamento resultante. Curvas de carga-deslocamento foram obtidas e a dureza da síntese determinada a partir da inclinaçao inicial dessas curvas. A fixaçao com parafusos mostrou maior rigidez inicial, mas nao foi superior estatisticamente à fixaçao com fio de Kirschner (p > 0,05). O grupo em que foi utilizado parafuso apresentou falência por quebra, enquanto no grupo em que foi usado fio de Kirschner esse padrÝo nÝo foi encontrado.


Subject(s)
Humans , Adult , Middle Aged , Biomechanical Phenomena , Hallux Valgus/surgery , Osteotomy , Cadaver , Statistics, Nonparametric
18.
Acta fisiátrica ; 2(3): 18-: 21-20, 23, dez. 1995. tab, graf
Article in Portuguese | LILACS | ID: lil-310055

ABSTRACT

Objetivos: Avaliaçäo da técnica FES em pacientes com patologias neurológicas diversas, utilizando equipamentos desenvolvidos pela Engenharia Biomédica do Hospital de Clínicas de Porto Alegre. Os objetivos principais deste trabalho säo: reduçäo da espasticidade muscular, fortalecimento muscular e melhora no padräo de marcha. Material: FES-II portátil, 2 canais, Engenharia Biomédica - HCPA; FES-II clínico, 2 canais, Engenharia Biomédica - HCPA. Estes equipamentos FES possuem as seguintes características principais: Canais: 2 canais isolados; Amplitude da corrente de saída: 0 a 80 mA; Largura dos pulsos: 100 a 700µs; Freqüência dos pulsos: 10 a 60 Hz; Trem de pulsos (Tempos de ataque, sustentaçäo, descida e repouso): ajustáveis; Controle Automático e Manual; Marcha automaticamente assistida (utilizando duas palmilhas especialmente desenvolvidas). Métodos: Metodologia da Escola de Lubljana. Sessöes periódicas de 10 minutos cada, aplicadas a pacientes previamente selecionados. Os resultados foram avaliados pela análise dos padröes de marcha e o exame clínico dos músculos estimulados.


Subject(s)
Humans , Electric Stimulation Therapy , Gait , Muscle Spasticity
19.
Odontol. USF ; 10(1/2): 85-102, jan.-dez. 1992.
Article in Portuguese | LILACS, BBO | ID: biblio-852209

ABSTRACT

Este trabalho tem por finalidade discorrer sobre as interações do tabagismo (fumo) e a Periodontia, através da revisão atual da literatura específica, onde serão considerados alguns tópicos, relacionando aspectos sistêmicos, orais e mais especificamente periodontais


Subject(s)
Periodontal Diseases/pathology , Tobacco
SELECTION OF CITATIONS
SEARCH DETAIL